Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 30.924
Filtrar
1.
BMC Neurosci ; 25(1): 21, 2024 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-38609841

RESUMO

The prevalence of electronic screens in modern society has significantly increased our exposure to high-energy blue and violet light wavelengths. Accumulating evidence links this exposure to adverse visual and cognitive effects and sleep disturbances. To mitigate these effects, the optical industry has introduced a variety of filtering glasses. However, the scientific validation of these glasses has often been based on subjective reports and a narrow range of objective measures, casting doubt on their true efficacy. In this study, we used electroencephalography (EEG) to record brain wave activity to evaluate the effects of glasses that filter multiple wavelengths (blue, violet, indigo, and green) on human brain activity. Our results demonstrate that wearing these multi-colour light filtering glasses significantly reduces beta wave power (13-30 Hz) compared to control or no glasses. Prior research has associated a reduction in beta power with the calming of heightened mental states, such as anxiety. As such, our results suggest that wearing glasses such as the ones used in this study may also positively change mental states, for instance, by promoting relaxation. This investigation is innovative in applying neuroimaging techniques to confirm that light-filtering glasses can induce measurable changes in brain activity.


Assuntos
Ondas Encefálicas , Humanos , Cor , Eletroencefalografia , Ansiedade , Emoções
5.
J Exp Biol ; 227(7)2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38586934

RESUMO

In many animals, ultraviolet (UV) vision guides navigation, foraging, and communication, but few studies have addressed the contribution of UV signals to colour vision, or measured UV discrimination thresholds using behavioural experiments. Here, we tested UV colour vision in an anemonefish (Amphiprion ocellaris) using a five-channel (RGB-V-UV) LED display. We first determined that the maximal sensitivity of the A. ocellaris UV cone was ∼386 nm using microspectrophotometry. Three additional cone spectral sensitivities had maxima at ∼497, 515 and ∼535 nm. We then behaviourally measured colour discrimination thresholds by training anemonefish to distinguish a coloured target pixel from grey distractor pixels of varying intensity. Thresholds were calculated for nine sets of colours with and without UV signals. Using a tetrachromatic vision model, we found that anemonefish were better (i.e. discrimination thresholds were lower) at discriminating colours when target pixels had higher UV chromatic contrast. These colours caused a greater stimulation of the UV cone relative to other cone types. These findings imply that a UV component of colour signals and cues improves their detectability, which likely increases the prominence of anemonefish body patterns for communication and the silhouette of zooplankton prey.


Assuntos
Visão de Cores , Perciformes , Animais , Cor , Células Fotorreceptoras Retinianas Cones/fisiologia , Percepção de Cores/fisiologia , Raios Ultravioleta
6.
Proc Biol Sci ; 291(2020): 20240016, 2024 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-38565157

RESUMO

An emerging consensus suggests that evolved intraspecific variation can be ecologically important. However, evidence that evolved trait variation within vertebrates can influence fundamental ecosystem-level processes remains sparse. In this study, we sought to assess the potential for evolved variation in the spotted salamander (Ambystoma maculatum) to affect aquatic ecosystem properties. Spotted salamanders exhibit a conspicuous polymorphism in the colour of jelly encasing their eggs-some females produce clear jelly, while others produce white jelly. Although the functional significance of jelly colour variation remains largely speculative, evidence for differences in fecundity and the morphology of larvae suggests that the colour morphs might differ in the strength or identity of ecological effects. Here, we assessed the potential for frequency variation in spotted salamander colour morphs to influence fundamental physiochemical and ecosystem properties-dissolved organic carbon, conductivity, acidity and primary production-with a mesocosm experiment. By manipulating colour morph frequency across a range of larval densities, we were able to demonstrate that larva density and colour morph variation were ecologically relevant: population density reduced dissolved organic carbon and increased primary production while mesocosms stocked with white morph larvae tended to have higher dissolved organic carbon and conductivity. Thus, while an adaptive significance of jelly coloration remains hypothetical, our results show that colour morphs differentially influence key ecosystem properties-dissolved organic carbon and conductivity.


Assuntos
Matéria Orgânica Dissolvida , Ecossistema , Animais , Feminino , Cor , Ambystoma , Larva
7.
Anim Cogn ; 27(1): 31, 2024 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-38592559

RESUMO

We studied how different types of social demonstration improve house sparrows' (Passer domesticus) success in solving a foraging task that requires both operant learning (opening covers) and discrimination learning (preferring covers of the rewarding colour). We provided learners with either paired demonstration (of both cover opening and colour preference), action-only demonstration (of opening white covers only), or no demonstration (a companion bird eating without covers). We found that sparrows failed to learn the two tasks with no demonstration, and learned them best with a paired demonstration. Interestingly, the action of cover opening was learned faster with paired rather than action-only demonstration despite being equally demonstrated in both. We also found that only with paired demonstration, the speed of operant (action) learning was related to the demonstrator's level of activity. Colour preference (i.e. discrimination learning) was eventually acquired by all sparrows that learned to open covers, even without social demonstration of colour preference. Thus, adding a demonstration of colour preference was actually more important for operant learning, possibly as a result of increasing the similarity between the demonstrated and the learned tasks, thereby increasing the learner's attention to the actions of the demonstrator. Giving more attention to individuals in similar settings may be an adaptive strategy directing social learners to focus on ecologically relevant behaviours and on tasks that are likely to be learned successfully.


Assuntos
Aprendizagem por Discriminação , Aprendizagem , Humanos , Animais , Cor , Recompensa
8.
Eur Respir J ; 63(4)2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38609095

RESUMO

BACKGROUND: A validated 4-point sputum colour chart can be used to objectively evaluate the levels of airway inflammation in bronchiectasis patients. In the European Bronchiectasis Registry (EMBARC), we tested whether sputum colour would be associated with disease severity and clinical outcomes. METHODS: We used a prospective, observational registry of adults with bronchiectasis conducted in 31 countries. Patients who did not produce spontaneous sputum were excluded from the analysis. The Murray sputum colour chart was used at baseline and at follow-up visits. Key outcomes were frequency of exacerbations, hospitalisations for severe exacerbations and mortality during up to 5-year follow-up. RESULTS: 13 484 patients were included in the analysis. More purulent sputum was associated with lower forced expiratory volume in 1 s (FEV1), worse quality of life, greater bacterial infection and a higher bronchiectasis severity index. Sputum colour was strongly associated with the risk of future exacerbations during follow-up. Compared to patients with mucoid sputum (reference group), patients with mucopurulent sputum experienced significantly more exacerbations (incident rate ratio (IRR) 1.29, 95% CI 1.22-1.38; p<0.0001), while the rates were even higher for patients with purulent (IRR 1.55, 95% CI 1.44-1.67; p<0.0001) and severely purulent sputum (IRR 1.91, 95% CI 1.52-2.39; p<0.0001). Hospitalisations for severe exacerbations were also associated with increasing sputum colour with rate ratios, compared to patients with mucoid sputum, of 1.41 (95% CI 1.29-1.56; p<0.0001), 1.98 (95% CI 1.77-2.21; p<0.0001) and 3.05 (95% CI 2.25-4.14; p<0.0001) for mucopurulent, purulent and severely purulent sputum, respectively. Mortality was significantly increased with increasing sputum purulence, hazard ratio 1.12 (95% CI 1.01-1.24; p=0.027), for each increment in sputum purulence. CONCLUSION: Sputum colour is a simple marker of disease severity and future risk of exacerbations, severe exacerbations and mortality in patients with bronchiectasis.


Assuntos
Bronquiectasia , Fosfatos de Cálcio , Escarro , Adulto , Humanos , Estudos Prospectivos , Escarro/microbiologia , Cor , Qualidade de Vida , Bronquiectasia/diagnóstico , Bronquiectasia/microbiologia , Sistema de Registros
9.
BMC Oral Health ; 24(1): 471, 2024 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-38637799

RESUMO

OBJECT: This study aimed to investigate the changes in the translucency and color of four different multi-layered zirconia materials when the sintering temperature were inaccurate. MATERIALS AND METHODS: Two hundred zirconia samples (11 × 11 × 1.0 mm) of four multi-layered zirconia, Upcera TT-GT (UG), Upcera TT-ML (UM), Cercon xt ML (CX), and Lava Esthetic (LE), were divided into five subgroups according to the sintering temperature: L1 (5% lower temperature), L2 (2.5% lower temperature), R (recommended sintering temperature), H2 (2.5% higher temperature), H1 (5% higher temperature). After sintering, color coordinates were measured. Then the translucency parameter (TP) values, and the color differences (between the inaccurate sintering temperature and the recommended temperature) of each zirconia specimen were calculated. Statistical analysis was performed by using three-way ANOVA tests, the one-way ANOVA, and Tukey's post hoc test. RESULTS: Three-way ANOVA results showed that material type, sintering temperature, specimen section, and their interactions significantly influenced the TP values (except for the interactions of specimen section and sintering temperature) (P < .05). TP values of zirconia specimens were significantly different in the inaccurate sintering temperatures (P < .05), except for the cervical and body sections of UG group (P > .05). Compared with recommended sintering temperature, higher sintering temperature caused higher TP values for CX, but lower for LE. Three-way ANOVA results showed that material type, sintering temperature, and their interactions significantly influenced the ∆E00 values (P < .05). There were no significant differences in ∆E00 values of UM and CX groups at different inaccurate sintering temperatures, and were clinical imperception (except for UM-L1) (∆E00 < 1.25). ∆E00 values of all zirconia specimens showed clinically acceptable (∆E00 < 2.23). CONCLUSION: The deviations in sintering temperature significantly influenced the translucency and color of tested multi-layered zirconia. The trends of translucency in the multi-layered zirconia depended on material type and the color changes of all zirconia materials were clinically acceptable at inaccurate sintering temperatures.


Assuntos
Cerâmica , Zircônio , Humanos , Temperatura , Teste de Materiais , Propriedades de Superfície , Cor
10.
BMC Oral Health ; 24(1): 472, 2024 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-38641578

RESUMO

PURPOSE: The aim of the current study was to evaluate the effect of simulated gastric acid on the color and translucency of different indirect restorative materials. MATERIALS AND METHODS: A total of 36 disc-shaped samples were cut by using an isomet saw and divided into four equal groups (n = 9) according to the material type: Group Z: translucent zirconia (Ceramill® Zolid ht.+ preshade, Amann Girrbach, Koblach, Austria); Group E: lithium disilicate (IPS e.max CAD, Ivoclar Vivadent AG, Schaan, Liechtenstein); Group C: resin nanoceramic (Cerasmart, GC, Tokyo, Japan); Group P: polyether ether ketone (PEEK) (Bettin Zirconia Dentale Italy) veneered with indirect high impact polymer composite (HIPC) (breCAM HIPC, Bredent GmbH & Co. KG, Germany). The samples were immersed in simulated gastric acid (HCl, pH 1.2) for 96 hours at 37 °C in an incubator. The color change (ΔE00) and translucency (RTP00) were measured every 9.6 hours (one-year clinical simulation) of immersion in simulated gastric acid. RESULTS: For color change (∆E00) and translucency (RTP00) among the tested materials, there was a highly statistically significant difference (P < 0.001) after every year of follow-up. The color change in both Z and G groups was the lowest after 1 year of acid immersion, followed by that in group H, and the highest change in color was recorded in group P. CONCLUSION: High translucent zirconia is recommended in patients who are concerned about esthetic, especially with acidic oral environment.


Assuntos
Cerâmica , Materiais Dentários , Humanos , Teste de Materiais , Zircônio , Propriedades de Superfície , Cor , Desenho Assistido por Computador
12.
PLoS One ; 19(4): e0301384, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38574047

RESUMO

A comprehensive analysis of outdoor weathering and soil burial of cork during 1-year experiments was carried out with measurements of CIELAB color parameters, cellular observations by scanning electron microscopy, and surface chemical features analysed by ATR-FTIR and wet chemical analysis. Cork applied in outdoor conditions above and below ground retained its physical structure and integrity without signs of deterioration or fracturing. The cellular structure was maintained with some small changes at the one-cell layer at the surface, featuring cellular expansion and minute cell wall fractures. Surface color and chemistry showed distinct results for outdoor exposure and soil burial. The weathered cork surfaces acquired a lighter color while the soil buried cork surfaces became darker. With outdoor weathering, the cork polar solubles increased (13.0% vs. 7.6% o.d. mass) while a substantial decrease of lignin occurred (about 28% of the original lignin was removed) leading to a suberin-enriched cork surface. The chemical impact on lignin is therefore responsible for the surface change towards lighter colors. Soil-burial induced hydrolysis of ester bonds of suberin and xylan, and the lignin-enriched cork surface displayed a dark brown color. FTIR and wet chemical results were consistent. Overall cork showed a considerable structural and physical stability that allows its application in outdoor conditions, namely for building façades or other surfacing applications. Architects and designers should take into account the color dynamics of the cork surfaces.


Assuntos
Lignina , Tempo (Meteorologia) , Lignina/química , Cor , Solo
13.
São Paulo; s.n; 20240301. 104 p.
Tese em Português | LILACS, BBO - Odontologia | ID: biblio-1532259

RESUMO

A fim de conter o avanço das lesões incipientes de cárie (LMB: lesões de mancha branca) e, oportunamente, de minimizar seu aspecto estético insatisfatório, a infiltração com material resinoso fotopolimerizável de baixa viscosidade e alto coeficiente de penetração vem sendo indicada. Contudo, nem sempre se consegue mascarar as LMB por completo, talvez principalmente em dentes escurecidos. Avaliou-se, pois, in vitro, o efeito do clareamento como complementação à infiltração resinosa, na dissimulação (diferença de cor do esmalte tratado vs. adjacente) de LMB em esmalte bovino artificialmente escurecido, comparativamente ao normal. Fragmentos de 6 x 3 mm, obtidos de incisivos bovinos, foram planificados e polidos, avaliados quanto à microdureza superficial (KHN, 50 g, 10 s), e distribuídos em sete grupos (n=15): N.L, N.LI, NB.LIB, E.L, E.LI, EB.LIB e C. O esmalte dos espécimes dos grupos E foi artificialmente escurecido (100 ml de água destilada / 25 g de café solúvel, 15 dias; E: escurecido), e o daqueles dos grupos N, não (N: normal). Na metade direita (região tratada - 3 x 3 mm) de todos eles, então, determinou-se uma LMB (tampão de acetato 50 mM, 64 horas, 37 oC), que não recebeu qualquer tratamento (L: lesão nenhum tratamento), ou foi apenas infiltrada H3PO4 37% / 10 s; Icon®-Dry / 30 s; Icon®- Infiltrant / 3 min + 1 min; LI: lesão infiltrada), ou infiltrada e, como o esmalte adjacente (metade esquerda, região referência/baseline - 3 x 3 mm), submetida a clareamento/bleaching (Opalescence Boost 40%, 3x de 20 min cada; LIB: lesão infiltrada e clareada; NB e EB: esmalte adjacente normal ou escurecido clareado). O esmalte de ambas as metades dos espécimes do grupo C (C: controle) não foi submetido a nada além da planificação e do polimento. Determinou-se os valores de E00, L, a e b (fórmula CIEDE2000), considerando-se como referência/baseline, em um mesmo espécime, a superfície de esmalte adjacente (metade esquerda) àquela devidamente desmineralizada / desmineralizada e tratada (metade direita) e, como a referência, submetida, ou não, a clareamento dentário. Para o grupo controle, tal diferença foi determinada entre suas duas metades. Considerando-se como fatores experimentais a condição inicial do esmalte (em 2 níveis) e o tratamento da LMB, bem como do esmalte adjacente, quando pertinente (em 3 níveis), analisou-se estatisticamente os dados por meio de ANOVA a 2 critérios e teste de Tukey. Para comparar cada um dos grupos experimentais entre si e com o grupo C, empregou-se o teste de Kruskal-Wallis e o de Dunn para E00, L e a, e ANOVA a 1 fator e teste de Tukey para b. Em todos os casos adotou-se =0,05. Independentemente se o clareamento é realizado, ou não, a infiltração resinosa é capaz de mascarar as LMB tanto no esmalte normal, quanto no escurecido. Ora, é indiferente realizar o clareamento como complementação à infiltração resinosa na dissimulação de LMB.


Assuntos
Clareamento Dental , Cor , Estética
14.
BMC Oral Health ; 24(1): 384, 2024 Mar 26.
Artigo em Inglês | MEDLINE | ID: mdl-38528493

RESUMO

BACKGROUND: The purpose of the study is to analyse the effects of different inhaled asthma medications (IAMs) on the color change of dental restorative materials (DRMs). METHODS: In total, 192 samples were taken from six different DRMs: [Filtek Z550 (nanohybrid composite), Fusio Liquid Dentin (Self-adhering flowable composite), Filtek Ultimate (nanofilled flowable composite), Dyract XP (compomer), Fuji II LC (resin-modified glass ionomer), Fuji IX Fast (self-cured-packable glass ionomer), (n = 32)]. After the initial color values (CIELab) of DRMs were measured by using a spectrophotometer, each sample was exposed to the same IAMs via nebulizer according to the four different inhaled therapies and measurements were repeated on the 7th & 21st days. RESULTS: In all IAM groups, DRM with the least amount of ΔE was nanohybrid composite, while the highest ΔE was found in Fuji II LC. Among all experimental groups, only Fuji II LC which was administered the combined medication, exceeded the clinically unacceptable threshold (ΔE = 3.3) on 7th & 21st days. CONCLUSIONS: Consequently, important factors affecting the susceptibility to color stability are the type of IAMs, the administration time-dosage, and the type of DRMs.


Assuntos
Resinas Compostas , Restauração Dentária Permanente , Humanos , Criança , Resinas Acrílicas , Dióxido de Silício , Cimentos de Ionômeros de Vidro , Teste de Materiais , Materiais Dentários , Cor
15.
J Appl Oral Sci ; 32: e20230348, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38537029

RESUMO

BACKGROUND: Repositioning guides are commonly employed in clinical studies to ensure consistent tooth color measurements. Yet, their influence on measured color remains uncertain. OBJECTIVE: This study evaluated the impact of repositioning guides' color and usage on tooth color measurement using a clinical spectrophotometer. METHODOLOGY: In total, 18 volunteers participated in this study, in which the color of their upper left central incisor and upper left canine was measured with or without repositioning guides (control). The guides were made from pink, blue, or translucent silicone, as well as an acetate-based bleaching tray. Tooth color was measured in triplicates using a clinical spectrophotometer based on the CIELAB system. The standard deviations of these readings were used to estimate reproducibility, and color differences (ΔE00) between the measurements with guides and the control were calculated. RESULTS: Repositioning guides had a minimal effect on L* values and no effect on b* values. The use of pink silicone increased a* values, whereas blue or translucent silicone reduced them. Irrespective of the evaluated tooth, the lowest ΔE00 values were observed for the translucent silicone and bleaching tray. The usage of guides only affected data variability for the L* color coordinate. CONCLUSION: Using repositioning guides can significantly impact the precision of tooth color measurement with a clinical spectrophotometer.


Assuntos
Incisivo , Clareamento Dental , Humanos , Cor , Reprodutibilidade dos Testes , Espectrofotometria , Silicones
16.
Microbiology (Reading) ; 170(3)2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38535895

RESUMO

Fluorescent proteins (FPs) have always been a crucial part of molecular research in life sciences, including the research into the human fungal pathogen Candida albicans, but have obvious shortcomings such as their relatively large size and long maturation time. However, the next generation of FPs overcome these issues and rely on the binding of a fluorogen for the protein to become fluorescently active. This generation of FPs includes the improved version of Fluorescence activating and Absorption Shifting Tag (iFAST). The binding between the fluorogen and the iFAST protein is reversible, thus resulting in reversible fluorescence. The fluorogens of iFAST are analogues of 4-hydroxylbenzylidene-rhodanine (HBR). These HBR analogues differ in spectral properties depending on functional group substitutions, which gives the iFAST system flexibility in terms of absorbance and emission maxima. In this work we describe and illustrate the application of iFAST as a protein tag and its reversible multi-colour characteristics in C. albicans.


Assuntos
Candida albicans , Rodanina , Humanos , Cor
17.
Vision Res ; 218: 108381, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38522412

RESUMO

EnChroma filters are aids designed to improve color vision for anomalous trichromats. Their use is controversial because the results of lab-based assessments of their effectiveness have so far largely failed to agree with positive anecdotal reports. However, the effectiveness of EnChroma filters will vary depending on the conditions of viewing, including whether the stimuli are broadband reflective surfaces or colors presented on RGB displays, whether illumination spectra are broadband or narrowband, the transmission spectra of particular filters, and the cone spectral sensitivity functions of the observer. We created a model of anomalous trichromatic color vision to predict the effects of EnChroma filters on the color signals impaired in anomalous trichromacy. Using the model we varied illumination, filter type and observer cone sensitivity functions, and tested the effect of presenting colors as broadband reflective surfaces or on RGB displays. We also used hyperspectral images to assess the impact of the filters on anomalous trichromats' color vision for natural scenes. Model results predicted that the filters should be broadly effective at enhancing anomalous trichromats' equivalent to L/(L + M) chromatic contrasts under a range of viewing conditions, but are substantially more effective for deuteranomals than for protanomals. The filters are predicted to be more effective for broadband reflective surfaces presented under broadband illuminants than for surfaces presented under narrowband illuminants or for colors presented on RGB displays. Since the potential impacts of contrast adaptation and perceptual learning are not considered in the model, it needs to be empirically validated. Results of empirical tests of the effects of EnChroma filters on deuteranomalous color vision in comparison with model predictions are presented in an accompanying paper (Somers et al., in prep.).


Assuntos
Defeitos da Visão Cromática , Visão de Cores , Humanos , Percepção de Cores , Testes de Percepção de Cores/métodos , Células Fotorreceptoras Retinianas Cones , Cor
18.
Vision Res ; 218: 108390, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38531192

RESUMO

Manufacturers of notch filter-based aids for color vision claim that their products can enhance color perception for people with anomalous trichromacy, a form of color vision deficiency (CVD). Anecdotal reports imply that people with CVD can have radically enhanced color vision when using the filters. However, existing empirical research largely focussed on the effect of notch filters on performance on diagnostic tests for CVD has not found that they have any substantial effect. Informed by a model of anomalous trichromatic color vision, we selected stimuli predicted to reveal the effects of EnChroma filters. Using these stimuli, we tested the ability of EnChroma filters to enhance color vision for 10 deuteranomalous trichromats in three experiments: 1. asymmetric color matching between test and control filter conditions, 2. color discrimination measured using four alternative forced-choice, and 3. color appearance measured using dissimilarity ratings to reconstruct subjective color spaces using multidimensional scaling. To investigate potential effects of long-term adaptation or perceptual learning, participants completed all three experiments at two time points, on first exposure to the filters, and after a week of regular use. We found a significant effect of the filters on color matches in the direction predicted by the model at both time points, implying that the filters can enhance the anomalous trichromatic color gamut. However, we found minimal effect of the filters on color discrimination at threshold. We found a significant effect of the filters in enhancing the appearance of colors along the red-green axis at the first time point, and a trend in the same direction at the second time point. Our results provide the first quantitative experimental evidence that notch filters can enhance color perception for anomalous trichromats.


Assuntos
Doenças Cardiovasculares , Defeitos da Visão Cromática , Visão de Cores , Humanos , Testes de Percepção de Cores/métodos , Percepção de Cores , Cor
19.
Niger J Clin Pract ; 27(3): 394-400, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38528362

RESUMO

BACKGROUND: As there is evidence showing the effects of alcohol on the surface properties of composite resins, it is of great importance to understand the effects of commonly consumed beverages on the discoloration of composite restorations in people who consume alcohol. AIM: The aim of this study was to investigate the changes in the color and translucency of composite resins immersed in different beverages after exposure to alcohol. METHODS: Disk-shaped samples from each composite resin (Filtek Z250 (Z250), Clearfil Majesty Esthetic (CME), and Esthelite Bulk Fill Flow (EBF), were prepared (n = 60) and randomly divided into two groups (exposed or unexposed to alcohol). The samples were immersed in distilled water, black tea, and coffee. The color parameter (∆E00) and translucency parameter (∆TP) were calculated after 24 h, 1 week, and 3 weeks. Four-way ANOVA and Tukey's post-hoc analysis were used for the statistical analysis (α = 0.05). RESULTS: Alcohol significantly increased the discoloration of Z250 and EBF in black tea. The discoloration of CME was not affected by alcohol exposure. Z250 and EBF showed clinically unacceptable discoloration (ΔE00 > 2.25) after immersion in black tea and coffee, whereas CME showed clinically unacceptable discoloration after immersion in black tea. Black tea caused the greatest color change in all composite materials regardless of alcohol exposure. EBF showed the lowest ΔTP values (∆TP = -1.82) at 3 weeks of immersion in black tea. CONCLUSIONS: The effect of alcohol on discoloration depended on the composite type used. The translucency of bulk-fill flowable composite decreased with alcohol exposure.


Assuntos
Bebidas Alcoólicas , Resinas Compostas , Humanos , Café , Propriedades de Superfície , Chá , Bebidas Alcoólicas/efeitos adversos , Cor
20.
N Engl J Med ; 390(11): e27, 2024 Mar 14.
Artigo em Inglês | MEDLINE | ID: mdl-38466610
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...